Closeout Air logoCloseout Air

00 Closeout paperwork

Your airflow spreadsheet, formatted as a client-ready report.

Done-for-you report formatting from your crew's existing Excel or CSV, for small commercial airside jobs. Send the workbook, get a branded PDF draft back, ready for your review and sign-off.

Request a report

$89 per eligible report. No subscription.

AHU-2.XLSXS-01150144S-02150157S-03120113S-08110S-1?8077DRAFT.PDFYOUR WORKBOOKCLIENT-READY DRAFT

01 Example spreadsheet, sample report

A spreadsheet in, a report out.

On the left, an example crew spreadsheet as it arrives. It is a separate example and not the source of the sample report. On the right, the five-page Harborline Exchange sample report, with design and measured CFM side by side and nothing missing filled in.

ahu-2-readings.csv, example spreadsheetDownload example CSV
OutletLocationDesign_CFMMeasured_CFM
S-01Supply diffuser, Open Office 101150144
S-02Supply diffuser, Open Office 101150157
S-03Supply diffuser, Open Office 102120113
S-04Supply diffuser, Open Office 102120126
S-05Supply diffuser, Conference 103200188
S-06Supply diffuser, Conference 103200209
S-07Supply diffuser, Corridor 1049084
S-08Supply diffuser, Break Room 105110BLANK
S-09Supply diffuser, Break Room 105110103
S-10Supply grille, Office 1068086
S-1?Label unclear in workbook (Office 107 or 108?)8077
S-12Supply diffuser, Office 1098074

Example spreadsheet export: one blank reading and one label that cannot be matched to a room.

closeout-air-sample-rev02.pdf, 5 pagesDownload revised sample report
Page 1 of the Harborline Exchange sample: cover
P1 Cover

Project details organized into a branded cover: Harborline Exchange, package CA-2601, 2 air systems, with a contractor logo and brand name placeholder.

Page 2 of the Harborline Exchange sample: systems guide
P2 Systems guide

Shows how the 2 air systems are organized and where to find each: AHU-01 on page 3, AHU-02 on page 4, certification appendix on page 5. Includes the DNL, LOA and NA legend.

Page 3 of the Harborline Exchange sample: ahu-01 readings
P3 AHU-01 readings

Design and measured CFM side by side for six outlets, W-101 to W-106. The supplied 0 at W-103 is kept as a reading and flagged to field note 1.

Page 4 of the Harborline Exchange sample: ahu-02 readings
P4 AHU-02 readings

Design and measured CFM side by side for E-201 to E-206. E-201 is marked LOA and E-203 has no reading; both are flagged to field notes 2 and 3, and nothing is filled in.

Page 5 of the Harborline Exchange sample: certification divider
P5 Certification divider

Closeout Air formats this divider. Any certification pages, marks and sign-off placed here are Contractor supplied, not prepared or certified by Closeout Air.

The sample shows two air systems and 12 outlets, with three numbered field notes on the readings pages. Pages 3 and 4 mark missing or blocked readings with the contractor legend (DNL, LOA, NA). Page 5 is a divider where the contractor adds their own certification pages; we do not certify, and the standard offer covers up to 100 outlets in total, across any number of air systems, in one workbook.

02 Price

Per eligible report$89

One flat price. No subscription.

Input
One Excel or CSV workbook, up to 100 outlets in total across any number of air systems.
Output
A branded PDF draft of the report.
Edits
One round of formatting edits.
Billing
Pay per report. Nothing recurring, nothing to cancel.

Inquire about a larger job

Request already approved? Sign in to pay for your approved report

03 What we do and don't

Formatting only. Your readings, your sign-off.

Carried over as supplied

Every reading and label in your workbook goes into the report exactly as you entered it. We do not correct, estimate or fill in numbers.

Blanks and unclear labels flagged

A missing reading or a label we cannot match is marked in the report and listed on the field notes page, so you can resolve it.

You review and sign off

The PDF is a draft. The contractor reviews it and signs off before it goes to your client.

Not field testing or certification

Closeout Air formats data you have already collected. We do not test, balance or measure anything, and we do not certify results.

04 Larger job

Inquire about a larger job.

For jobs with more than 100 outlets in total, across any number of air systems. Tell us the size and the deadline and we will reply with how we can help. This is an inquiry only: it is not the $89 standard report, and nothing is charged.

05 Request a report

Tell us what is due and when.

Closeout Air reads your request, confirms the job is a fit, and arranges the workbook handoff with you before any work starts. You can attach your spreadsheets (XLSX, XLS or CSV) now or send them at the handoff. Attachments are kept private and are not emailed. There is no checkout on this page.

  • 1 You send work email, outlet count, deadline and, if you like, your spreadsheets.
  • 2 We confirm fit and arrange any workbook handoff still needed.
  • 3 We start, then send your PDF draft.

? Report questions

(415) 439-0488